| SYSTEM
OVERVIEW |
|
System
overview:
|
Line
interactive tower UPS protects internetworking
and telecommunications equipment from blackouts,
brownouts, overvoltages, surges and line noise.
Maintains AC output during blackouts and continuously
corrects brownouts and overvoltages from 75
to 147 volts back to normal 120V levels. Supports
enhanced monitoring of UPS and line power
conditions via USB serial port, included PowerAlert
UPS monitoring software and cabling.
|
|
Voltage
compatibility:
|
120V
AC
|
|
Frequency
compatibility:
|
60Hz
|
| OUTPUT |
|
Output
volt amp capacity (VA):
|
1050
|
|
Output
watt capacity (watts):
|
705
|
|
Output
nominal voltage:
|
120V
AC
|
|
Output
voltage regulation:
|
LINE
MODE: Sine wave line voltage 120V (-18% /
+8%), BATTERY MODE: PWM sine wave output 120V
+/-5%
|
|
Output
frequency regulation:
|
LINE
MODE: Passes line frequency of 60Hz +/-10%
BATTERY MODE: Inverter output regulated to
60Hz +/-0.5Hz
|
|
Outlet
quantity / type:
|
6
NEMA 5-15R
|
|
Overload
protection:
|
12A
input breaker
|
| INPUT |
|
Maximum
input amps:
|
6.7A
/760 watts
|
|
Input
connection type:
|
NEMA
5-15P
|
|
Input
cord length:
|
6
ft., 16 gauge
|
|
Recommended
electrical service:
|
15A
120V
|
| BATTERY |
|
Full
load runtime:
|
8
minutes (1050VA)
|
|
Half
load runtime:
|
23
minutes (525VA)
|
|
DC
system voltage:
|
18
VDC
|
|
Typical
battery lifespan:
|
3-6
years, depending on usage
|
|
Battery
recharge rate:
|
2-4
hours to 90%
|
| VOLTAGE
REGULATION |
|
Voltage
regulation description:
|
Automatic
Voltage Regulation (AVR) circuits maintain
clean, regulated computer-grade 120V nominal
output, without using battery power, during
brownouts to 75V and overvoltages to 147V
|
|
Overvoltage
correction:
|
Input
voltages between 128 and 147VAC are reduced
by 12%
|
|
Direct
pass through:
|
Input
voltages between 108 and 127VAC are passed
on to connected equipment unchanged
|
|
Brownout
correction:
|
Input
voltages between 108 and 127VAC are passed
on to connected equipment unchanged
|
|
Severe
brownout correction:
|
Input
voltages between 75 and 92VAC are boosted
by 30%
|
| LEDS
ALARMS & SWITCHES |
|
Front
panel LEDs:
|
Includes
5 front panel LEDs to indicate BATTERY CHARGE
LEVEL, AC LINE POWER STATUS, VOLTAGE REGULATION
STATUS, UPS LOAD LEVEL and BATTERY LOW / REPLACE
information
|
|
Alarms:
|
Audible
alarm with 15 second delay sounds to indicate
loss of utility power. Alarm can be silenced
by pressing front panel alarm cancel button.
Once silenced, alarm will re-sound when approximately
2 minutes runtime remain.
|
|
Switches:
|
Includes
2 front panel switches - one main on/off power
switch and one dual function "alarm cancel"
/ "self test" button
|
| SURGE
/ NOISE SUPPRESSION |
|
AC
surge suppression:
|
480
joules
|
|
AC
suppression response time:
|
Instantaneous
|
|
EMI
/ RFI AC noise suppression:
|
Yes
|
| PHYSICAL |
|
Shipping
weight (lbs):
|
31
|
|
Shipping
weight (kg):
|
14.1
|
|
Unit
weight (lbs):
|
29
|
|
Unit
weight (kg):
|
13.2
|
|
Unit
Dimensions (HWD/in):
|
11.75
x 7.25 x 7.25
|
|
Unit
Dimensions (HWD/cm):
|
29.8
x 18.4 x 18.4
|
|
Shipping
Dimensions (HWD/in):
|
15
x 10.75 x 11.25
|
|
Shipping
Dimensions (HWD/cm):
|
38.1
x 27.3 x 28.6
|
|
Material
of construction:
|
Polycarbonate
|
|
Form
factors supported:
|
Tower
|
|
Cooling
method:
|
Convection
|
|
Battery
Access:
|
Battery
access door allows user replacement of UPS
batteries
|
| ENVIRONMENTAL |
|
Operating
Temperature:
|
+32 to +104 degrees Fahrenheit
0 to +40 degrees Celsius
|
|
Storage
Temperature:
|
+5 to +122 degrees Fahrenheit
-15 to +50 degrees Celsius
|
|
Relative
Humidity:
|
0
to 95%, non-condensing
|
|
Line
mode BTU/hr. (Max.):
|
61.5
|
|
Battery
mode BTU/hr. (Max.):
|
208.4
|
| COMMUNICATIONS |
|
Network
monitoring port:
|
Built-in
USB port supports on battery, low battery,
power restored, AC line voltage, DC battery
voltage, load percentage, battery charge current,
battery capacity, internal UPS temperature
and line frequency status messaging. Interface
supports timed inverter shutoff after unattended
shutdown, activate self-test and 10 second
reboot of connected equipment. Supports reboot
of all connected devices at once via software
interface. Compatible with Tripp Lite's PowerAlert
software.
|
|
Software
and cabling included:
|
Includes
PowerAlert UPS monitoring and auto-shutdown
software and cabling
|
|
WatchDog
compatibility:
|
Compatible
with Tripp Lite's Watchdog system service
to restore operation to locked equipment through
soft reboot of application / OS or hard power
off/on reboot of connected equipment - ideal
for unattended kiosk applications
|
| LINE
/ BATTERY TRANSFER |
|
Transfer
time from line power to battery mode:
|
2-4
milliseconds
|
|
Low
voltage transfer to battery power:
|
Switches
to battery power as line voltage decreases
to 75 volts or less. Resets back to line power
mode as line voltage increases to 79V or higher.
|
|
High
voltage transfer to battery power:
|
Switches
to battery power as line voltage increases
to 147 volts or higher. Resets back to line
power mode as line voltage decreases to 143V
or less.
|
| CERTIFICATIONS |
|
Certifications:
|
UL1778
(USA), cUL (Canada), Class B (emissions),
NOM (Mexico)
|
| WARRANTY |
|
Optional
coverage:
|
3-5
year warranties, plus next day and on-site
warranty coverage available for select opportunities.
Contact Tripp Lite for additional information.
|
|
Product
warranty:
|
2
year product warranty
|
|
Connected
equipment insurance (USA and Canada Only):
|
$250,000
connected equipment insurance (USA / Canada
only)
|
| SPECIAL
FEATURES |
|
Cold
Start:
|
Yes,
inverter can be "cold started" to enable temporary
AC output during a power failure
|
|
Appearance:
|
Attractive
gray tower UPS
|