Photos

Introduction
Tripp
Lite's SMART500RT1U intelligent, line interactive
rack/tower uninterruptible power supply prevents
data loss, downtime and equipment damage due to
power outages, voltage fluctuations and transient
surges. Requires only one rack space (1U) in a 2
or 4 post rack, with included accessories for upright
tower placement. Large internal batteries offer
17 minutes half load runtime and 5 minutes at full
load. Maintains regulated 120V nominal output without
using battery power during brownouts as low as 90V.
500VA / 300 watt power handling capability is compatible
with networking, telecom and other sensitive electronic
applications. Includes 6 UPS supported outlets with
a single outlet load bank that can be individually
controlled via software interface to reboot select
equipment on demand or shed less significant loads
to extend battery runtime for more critical equipment.
Includes 1 surge-only outlet for peripherals not
requiring battery backup. Supports simultaneous
remote monitoring of UPS and site power conditions
via built-in USB and DB9 monitoring ports. Includes
PowerAlert UPS monitoring and unattended shutdown
software with complete cabling. Built-in accessory
slot supports SNMP with optional SNMPWEBCARD adapter.
Emergency Power Off (EPO) interface offers option
for instantaneous power-off of UPS and connected
equipment in the case of fire or emergency situation.
Multi-function audible alarms and set of 5 front
panel LEDs offer at-a-glance notification of UPS
and line power status. Network-grade AC surge suppression
protects equipment from damage and performance problems
resulting from transient surges and line noise.
Attractive all-black color scheme. Two year warranty
with $250,000 connected equipment insurance (USA
& Canada only).
Application
Ideal
for protection of fileservers, network accessories
and telecommunications equipment in server rooms,
internetworking closets, co-location racks, kiosks
and a variety of other locations. Common applications
include any mix of servers, workstations, hubs,
routers, concentrators, IP telephony and traditional
PBX switching systems.
Features
-
SMART 500RT1U line interactive UPS offers battery
derived sine wave AC output during power outages,
voltage regulation during brownouts, plus network-grade
AC surge suppression
-
500VA / 300 watt power handling capability compatibile
with networking, telecom and other sensitive electronic
devices
-
Supports 1U rackmount installation in 2 or 4 post
rack enclosures, upright tower placement also
supported - mounting accessories included
-
Large internal batteries offer runtimes of 17
minutes at half load (250VA / 150 watts) and 5
minutes at full load (500VA / 300 watts)
-
Maintains regulated 120V nominal output during
brownouts as low as 90V
-
Includes 6 UPS-supported outlets, with one single
outlet load bank that can be powered off and back
on again via software interface. One additional
surge-only outlet powers accessories not requiring
battery support
-
PowerAlert UPS monitoring and unattended shutdown
software enables configurable network broadcast
messaging, email notification, event logging and
running user-defined script commands
-
Offers simultaneous monitoring by up to 3 directly-connected
devices through included USB, DB9 and SNMP* interfaces
(*requires optional SNMPWEBCARD), or the monitoring
of any number of additional UPS systems over IP
with included PowerAlert monitoring software.
-
Communications ports support messaging of UPS
and line power status, including on-battery, low-battery,
power restored, AC line voltage, DC battery voltage
and remaining battery capacity
-
Supports timed inverter shutoff after unattended
shutdown, activate self-test and UPS output power
control for delayed or immediate reboot of connected
devices
-
Supports Tripp Lite's WatchDog software application
to restore unresponsive programs by systematically
restarting applications, operating systems and
ultimately rebooting completely locked computers
by momentarily switching UPS power off and back
on again (requires optional WATCHDOGSW)
-
Built-in accessory slot supports SNMP with optional
SNMPWEBCARD adapter
-
Emergency Power Off (EPO) interface with cable
-
Multi-function audible alarms and set of 5 front
panel LEDs
-
Network-grade AC surge suppression
-
Attractive all-black color scheme
-
UPS battery set ships fully assembled and ready
for installation, no time consuming connection
of internal batteries by user is necessary
-
Two year warranty with $250,000 connected equipment
insurance (USA & Canada only)
Specifications
| SYSTEM
OVERVIEW |
|
System
overview:
|
Line
interactive 1U rack / tower UPS with protection
from blackouts, brownouts, surges and line
noise. Maintains AC output during blackouts
and continuously corrects brownouts as low
as 90 volts back to usable levels. Supports
enhanced monitoring of UPS and line power
conditions via built-in USB and DB9 serial
ports, included PowerAlert monitoring software
and complete cabling. Includes slot for SNMPWEBCARD
accessory. Single built-in outlet load management
bank offers remote reboot of selected loads
via software interface or load shedding to
enhance battery runtime for the most critical
loads during blackouts. Supports 1U rackmount
and upright tower form factors with included
mounting hardware.
|
|
Voltage
compatibility:
|
120V
AC
|
|
Frequency
compatibility:
|
60
Hz
|
| OUTPUT |
|
Output
volt amp capacity (VA):
|
500
|
|
Output
watt capacity (watts):
|
300
|
|
Output
nominal voltage:
|
120V
AC
|
|
Output
voltage regulation:
|
LINE
MODE: Sine wave line voltage 120V (-15% +13%),
BATTERY MODE: PWM sine wave output within
10% of 120V
|
|
Output
frequency regulation:
|
LINE
MODE: Passes line frequency of 60Hz +/-10%
BATTERY MODE: Inverter output regulated to
60Hz +/-1Hz
|
|
Outlet
quantity / type:
|
7
NEMA 5-15R
|
|
Customized
load management receptacles:
|
Includes
single-outlet load bank that supports load
shedding and remote reboot on demand of locked
network devices. Controllable via PowerAlert
software to switch off optional loads, like
monitors, to increase available runtime for
servers and other critical devices.
|
|
Overload
protection:
|
Via
15A input breaker
|
| INPUT |
|
Maximum
input amps:
|
5.6A
|
|
Input
connection type:
|
NEMA
5-15P
|
|
Input
cord length:
|
10
ft., 14 gauge, Black
|
|
Recommended
electrical service:
|
15A
120V
|
| BATTERY |
|
Full
load runtime:
|
5
minutes (500VA)
|
|
Half
load runtime:
|
17
minutes (250VA)
|
|
DC
system voltage:
|
12
VDC
|
|
Typical
battery lifespan:
|
3-6
years, depending on usage
|
|
Battery
recharge rate:
|
2-4
hours to 90%
|
|
Replacement
Battery Cartridge:
|
RBC62-1U
|
| VOLTAGE
REGULATION |
|
Voltage
regulation description:
|
Line
interactive voltage regulation system corrects
brownouts as low as 90 volts back to usable
120V nominal levels
|
|
Brownout
correction:
|
Input
voltages between 90 and 108 are boosted by
14%
|
| LEDS
ALARMS & SWITCHES |
|
Front
panel LEDs:
|
5
front panel LEDs - green POWER LED, green
AVR LED, 3-color BATTERY CHARGE LED, 3-color
OUTPUT LOAD LEVEL LED, red BATTERY WARNING
LED.
|
|
Alarms:
|
Audible
alarm warns of power failure, overload, UPS
fault and low battery conditions
|
|
Switches:
|
Includes
2 front panel mounted push-button switches
for system enable, self-test and alarm cancel
functions
|
| SURGE
/ NOISE SUPPRESSION |
|
AC
surge suppression:
|
480
joules
|
|
AC
suppression response time:
|
Instantaneous
|
|
EMI
/ RFI AC noise suppression:
|
Yes
|
| PHYSICAL |
|
Shipping
weight (lbs):
|
19.9
|
|
Shipping
weight (kg):
|
9
|
|
Unit
weight (lbs):
|
17.6
|
|
Unit
weight (kg):
|
8
|
|
Unit
Dimensions (HWD/in):
|
1.75
x 17.5 x 11.75
|
|
Unit
Dimensions (HWD/cm):
|
4.45
x 44.5 x 29.8
|
|
Shipping
Dimensions (HWD/in):
|
5
x 22.5 x 16
|
|
Shipping
Dimensions (HWD/cm):
|
12.7
x 57.2 x 40.6
|
|
Material
of construction:
|
Steel
|
|
Form
factors supported:
|
Rack/Tower
(1U)
|
|
Battery
Access:
|
Battery
access door allows hot swap battery replacement
without powering connected equipment off
|
| ENVIRONMENTAL |
|
Operating
Temperature:
|
+32
to +104 degrees Fahrenheit / 0 to +40 degrees
Celsius
|
|
Storage
Temperature:
|
+5 to +122 degrees Fahrenheit / -15 to +50
degrees Celsius
|
|
Relative
Humidity:
|
0
to 95%, non-condensing
|
|
Line
mode BTU/hr. (Max.):
|
65.1
|
|
Battery
mode BTU/hr. (Max.):
|
437.1
|
| COMMUNICATIONS |
|
Network
monitoring port:
|
Includes
2 built-in monitoring ports, 1-USB & 1-DB9.
Each supports on battery, low battery, power
restored, AC line voltage, DC battery voltage,
load percentage, battery charge current, battery
capacity, internal UPS temperature and line
frequency status messaging. Interface supports
timed inverter shutoff after unattended shutdown,
activate self-test and 10 second reboot of
connected equipment. Supports reboot of all
connected devices at once or individual load
banks via software interface. Compatible with
Tripp Lite's PowerAlert and WatchDog software.
|
|
Software
and cabling included:
|
Includes
PowerAlert UPS monitoring software for network
and standalone operating systems. Ships with
complete USB and DB9 cabling.
|
|
SNMP
compatibility:
|
Built-in
accessory slot accommodates internal SNMP
/ Web card and other network accessories
|
|
WatchDog
compatibility:
|
Yes,
compatible with Tripp Lite's Watchdog system
service to restore operation to locked equipment
through soft reboot of application / OS or
hard power off/on reboot of connected equipment
- ideal for unattended kiosk applications
|
| LINE
/ BATTERY TRANSFER |
|
Transfer
time from line power to battery mode:
|
2-4
milliseconds
|
|
Low
voltage transfer to battery power:
|
90V
(resets to line power as line voltage increases
to 94V or higher)
|
|
High
voltage transfer to battery power:
|
136V
(resets to line power as line voltage decreases
to 132 or lower)
|
| CERTIFICATIONS |
|
Certifications:
|
UL1778
(USA), cUL (Canada), Class B (emissions),
NOM (Mexico), RoHS-Compliant
|
| WARRANTY |
|
Optional
coverage:
|
2
year product warranty
|
|
Product
warranty:
|
$250,000
connected equipment insurance (USA / Canada
only)
|
|
Connected
equipment insurance (USA and Canada Only):
|
3
year, 5 year, next day and on-site warranty
coverage available for select opportunities
|
| SPECIAL
FEATURES |
|
EPO
port:
|
Includes
RJ11 EPO (emergency power off) port and cable
|
|
TVSS
grounding:
|
Includes
back panel grounding point with thumbscrew
for data line surge suppressors and other
network accessories requiring a safe grounding
point
|
|
Cold
Start:
|
Yes,
inverter can be "cold started" to enable temporary
AC output during a power failure
|
|
Appearance:
|
Attractive
all-black color scheme
|
Package
Contents
- Retail
Box
- SMART
500RT1U UPS System
-
Mounting hardware
-
Cabling for USB & DB9 monitoring and EPO switching
-
PowerAlert unattended shutdown and UPS/Power monitoring
software
-
Warranty information and instruction manual
|