| SYSTEM
OVERVIEW |
|
System
overview:
|
1500VA
line interactive UPS for PCs and workstations,
Expandable battery runtime, Battery supported
AC outlets with surge suppression, Surge suppression-only
outlets, Audible alarms, Self-test/alarm cancel
switch, Automatic voltage regulation (AVR),
Cold-start ability, Single line TEL protection,
Network ethernet line surge suppression, Status
indicator LEDs, USB monitoring port, USB cable,
Attractive all-black cabinet, Hotswappable
batteries, Battery access panel
|
|
Voltage
compatibility:
|
120V
AC
|
|
Frequency
compatibility:
|
60Hz
|
| OUTPUT |
|
Output
volt amp capacity (VA):
|
1500
|
|
Output
watt capacity (watts):
|
940
|
|
Output
nominal voltage:
|
120VAC
|
|
Output
voltage regulation:
|
LINE
MODE: Sine wave line voltage 120V (-18% /
+8%), BATTERY MODE: PWM sine wave output 120V
+/-5%
|
|
Output
frequency regulation:
|
LINE
MODE: Passes line frequency of 60Hz +/-10%
BATTERY MODE: Inverter output regulated to
60Hz +/-0.5Hz
|
|
Outlet
quantity / type:
|
8
NEMA 5-15R
|
| INPUT |
|
Maximum
input amps:
|
12A
|
|
Input
connection type:
|
NEMA
5-15P
|
|
Input
cord length:
|
6
ft., 14 gauge
|
|
Recommended
electrical service:
|
15A
120V
|
| BATTERY |
|
Full
load runtime:
|
5
minutes (1500VA / 940 watts) - add 1 BP24V14
for 14 minutes
|
|
Half
load runtime:
|
14
minutes (750VA / 470 watts) - add 1 BP24V14
for 34 minutes
|
|
DC
system voltage:
|
24VDC
|
|
Typical
battery lifespan:
|
3-6
years, depending on usage
|
|
Battery
recharge rate:
|
2-4
hours to 90%
|
|
Replacement
Battery Cartridge:
|
RBC51
(quantity 2)
|
| VOLTAGE
REGULATION |
|
Voltage
regulation description:
|
Automatic
Voltage Regulation (AVR) circuits maintain
clean, regulated computer-grade 120V nominal
output, without using battery power, during
brownouts to 75V and overvoltages to 147V
|
|
Overvoltage
correction:
|
Input
voltages between 128 and 147VAC are reduced
by 12%
|
|
Direct
pass through:
|
Input
voltages between 108 and 127VAC are passed
on to connected equipment unchanged
|
|
Brownout
correction:
|
Input
voltages between 93 and 107VAC are boosted
by 14%
|
|
Severe
brownout correction:
|
Input
voltages between 75 and 92VAC are boosted
by 30%
|
| LEDS
ALARMS & SWITCHES |
|
Front
panel LEDs:
|
4
front panel LEDs indicate line power status,
battery power status, battery low/replace
status and voltage regulation operation
|
|
Alarms:
|
Audible
alarm with 15 second delay sounds to indicate
loss of utility power. Alarm can be silenced
by pressing front panel alarm cancel button.
Once silenced, alarm will re-sound when approximately
2 minutes runtime remain.
|
|
Switches:
|
Includes
2 front panel switches-one main on/off power
switch and one dual function "alarm cancel"
/ "self test" button
|
| SURGE
/ NOISE SUPPRESSION |
|
AC
surge suppression:
|
480
joules
|
|
AC
suppression response time:
|
Instantaneous
|
|
Dataline
suppression:
|
Tel/DSL
or Ethernet
|
|
EMI
/ RFI AC noise suppression:
|
Yes
|
| PHYSICAL |
|
Shipping
weight (lbs):
|
34.1
|
|
Shipping
weight (kg):
|
15.5
|
|
Unit
weight (lbs):
|
32.2
|
|
Unit
weight (kg):
|
14.6
|
|
Unit
Dimensions (HWD/in):
|
11.75
x 7.25 x 7.5
|
|
Unit
Dimensions (HWD/cm):
|
29.8
x 18.4 x 19.1
|
|
Shipping
Dimensions (HWD/in):
|
15.5
x 11 x 11.25
|
|
Shipping
Dimensions (HWD/cm):
|
39.4
x 28 x 28.6
|
|
Material
of construction:
|
Polycarbonate
|
|
Form
factors supported:
|
Tower
|
|
Cooling
method:
|
Fan
|
|
Battery
Access:
|
Battery
access door allows user replacement of UPS
batteries, hot swappable battery replacement
supported
|
| ENVIRONMENTAL |
|
Operating
Temperature:
|
+32
to +104 degrees Fahrenheit 0 to +40 degrees
Celsius
|
|
Storage
Temperature:
|
+5
to +122 degrees Fahrenheit -15 to +50 degrees
Celsius
|
|
Relative
Humidity:
|
0
to 95%, non-condensing
|
| COMMUNICATIONS |
|
Network
monitoring port:
|
USB
|
|
Software
and cabling included:
|
USB
cabling included, PowerAlert software available
for free download at www.tripplite.com
|
|
WatchDog
compatibility:
|
Yes,
compatible with Tripp Lite's Watchdog system
service to restore operation to locked equipment
through soft reboot of application / OS or
hard power off/on reboot of connected equipment
- ideal for unattended kiosk applications
|
| LINE
/ BATTERY TRANSFER |
|
Transfer
time from line power to battery mode:
|
2-4
milliseconds
|
|
Low
voltage transfer to battery power:
|
Switches
to battery power as line voltage decreases
to 75 volts or less. Resets back to line power
mode as line voltage increases to 79V or higher.
|
|
High
voltage transfer to battery power:
|
Switches
to battery power as line voltage increases
to 147 volts or higher. Resets back to line
power mode as line voltage decreases to 143V
or less.
|
| CERTIFICATIONS |
|
Certifications:
|
Tested
to UL1778 (USA), CSA (Canada), NOM (Mexico),
FCC Class B (Emissions)
|
| WARRANTY |
|
Optional
coverage:
|
3-5
year warranties, plus next day and on-site
warranty coverage available. Contact Tripp
Lite for additional information.
|
|
Product
warranty:
|
2
year product warranty
|
|
Connected
equipment insurance (USA and Canada Only):
|
$200,000
connected equipment insurance (USA and Canada
only)
|
| SPECIAL
FEATURES |
|
Cold
Start:
|
Yes,
inverter can be "cold started" to enable temporary
AC output during a power failure
|
|
Appearance:
|
Attractive
black tower UPS
|
| BATTERY
PACK ACCESSORY (optional) |
|
Battery
Pack Accessory (optional):
|
BP24V14
or BP24V34 (Limit one on both packs)
|